3 Grid Levels (density at time t = 0.75) 
  Results:   2 Levels    /  3 Levels  
Contour lines of density on refinement grids (P=1)
     
|  | Level 0 | Level 1 | Level 2 | 
| Grids | 2 | 48 | 111 | 
| Cells | 67500 | 25792 | 187248 | 
  Benchmark 
| Task | P=1 | P=2, GuC-Factor=2 | P=4, GuC-Factor=2 | P=2, GuC-Factor=1 | P=4, GuC-Factor=1 | 
| s | % | s | % | s | % | s | % | s | % | 
| Integration | 3930 | 73.1 | 1848 | 62.0 | 930 | 53.5 | 2077 | 43.6 | 1045 | 38.3 | 
| Flux correction | 95 | 1.8 | 66 | 2.2 | 63 | 3.6 | 91 | 1.9 | 78 | 2.9 | 
| Boundary setting | 657 | 12.2 | 660 | 22.1 | 463 | 26.7 | 704 | 14.8 | 458 | 16.8 | 
| Recomposition | 271 | 5.0 | 231 | 7.7 | 176 | 10.1 | 1685 | 35.4 | 1015 | 37.2 | 
| Clustering | 177 | 3.3 | 67 | 2.2 | 35 | 2.0 | 69 | 1.4 | 36 | 1.3 | 
| Misc. | 243 | 4.5 | 110 | 3.7 | 70 | 4.0 | 131 | 3.0 | 85 | 3.5 | 
| Total / Parallel Efficiency | 5373 | 100.0 | 2982 | 90.1 | 1737 | 77.3 | 4756 | 56.5 | 2717 | 49.4 | 
|---|
If a relatively fine base grid is used, the choice of a larger GuC-Factor can decrease the overhead for partitioning and recomposition significantly. In this example, the partitioner can use up to 67500 units for GuC-Factor=1, while for GuC-Factor=2 only up to 16875 units are allowed.
<--- Problem description
-- 
RalfDeiterding - 04 Dec 2004